Klahanie (98075)
Klahanie 200A Electrical Panel Upgrade & Dual EV Charger Installation
Upgraded an obsolete 125A panel to a 200A Square D service with dual 60A dedicated Level 2 EV charging circuits for a Klahanie craftsman home.
The Situation
The homeowner in Klahanie had recently taken delivery of two new electric vehicles (Tesla Model Y and Rivian R1S). The property had an original 1994 split-bus 125-amp panel with no available breaker spaces, double-tapped neutrals, and severe busbar corrosion, preventing safe vehicle charging.
Diagnostic Finding
An NEC Article 220 load calculation indicated total peak demand with two 48-amp EV chargers would exceed 165 amps, far outstripping the existing 125-amp service. Thermal imaging also revealed elevated temperatures (138°F) on the main lug terminations under heavy evening loads.
Electrical Solution
Coordinated an approved scheduled service disconnection with Puget Sound Energy (PSE). Installed a new 200-amp outdoor meter base and an indoor Square D QO 42-space panel with whole-house Type 2 surge suppression. Ran heavy-gauge copper conductors through the crawlspace in rigid conduit to the garage, installing two dedicated 60A branch circuits equipped with smart dynamic load sharing.
Outcome & Safety Verification
Full 200A service established with clean 48A simultaneous Level 2 charging. The installation passed City of Sammamish building and electrical inspections on first submission with zero deficiencies.
“Our original panel was completely maxed out and running hot. The upgrade gave us total peace of mind and our cars charge overnight without tripping anything.”